The AQL table is read in three steps: from the lot size and the inspection level you get the code letter; from the letter you get the number of pieces to inspect; from the AQL you get Ac (defectives allowed) and Re (defectives that reject the lot).
Step 1 – Find the code letter
In the first table of ISO 2859-1, cross the lot size (N) with the inspection level. The most used level is II, the default general level; I and III inspect fewer or more pieces, while the special levels S-1…S-4 are meant for costly or destructive tests.
Example: a lot of 5,000 bottles, level II. The lot falls in the 3,201–10,000 range, so the code letter is L.
Step 2 – Read the sample size
In the master table (single sampling, normal inspection) each letter corresponds to a sample size. Letter L corresponds to 200 pieces, drawn at random from the whole lot, not just from the first carton.
Step 3 – Read Ac and Re in the AQL column
On the letter's row, in the column of the chosen AQL, you find two numbers: Ac, the maximum number of defective pieces with which the lot is accepted, and Re, the number from which the lot is rejected. Each defect class has its own AQL, and therefore its own Ac/Re.
| Class | AQL | Sample | Ac | Re |
|---|---|---|---|---|
| Critical | 0.65 | 200 | 3 | 4 |
| Major | 1.5 | 200 | 7 | 8 |
| Minor | 4.0 | 200 | 14 | 15 |
If you find 2 critical, 5 major and 9 minor defectives in the 200 pieces, every class is within Ac: the lot is accepted. A single class reaching Re is enough to reject the lot.
Arrows: when the cell has no numbers
Some cells contain an arrow instead of Ac/Re. It means that no suitable plan exists for the chosen AQL with that sample: follow the arrow to the first available plan and use its sample size, not that of the starting letter.
Example: a lot of 1,000 pieces, level II, letter J (80 pieces). With AQL 0.25 the cell has an upward arrow: move up to the plan of letter H, so 50 pieces, Ac 0, Re 1. If the sample size is equal to or larger than the lot, inspect 100%.
Normal, tightened, reduced
You always start with normal inspection. If 2 out of 5 or fewer consecutive lots are rejected, switch to tightened, with stricter criteria; go back to normal after 5 consecutive accepted lots. Reduced inspection, with smaller samples, may be adopted when quality is consistently good, following the switching rules of the standard and with the approval of the responsible authority.
Common mistakes
- Using the sample size of the starting letter even when the cell has an arrow.
- Drawing pieces only from the most convenient cartons: the sample must represent the whole lot.
- Applying one AQL to all defects instead of one per class.
- Reading Ac as a percentage of allowed defects: it is a number of pieces in the sample.
Try the example from this guide
The calculator opens with a lot of 5,000, level II and AQL 0.65 / 1.5 / 4.0.